HIOKI DT4221 Digital Multimeter

The Hioki DT4200 Digital Multimeter Series consist of a complete lineup of 9 models ranging from professional to industrial to pocket meters, delivering a super fast response rate and safety features that take electrical testing to a higher level.

The Hioki DT4200 Digital Multimeter Series consist of a complete lineup of 9 models ranging from professional to industrial to pocket meters, delivering a super fast response rate and safety features that take electrical testing to a higher level. The DT4221 is a pocket-sized digital multimeter designed specifically for electrical work requiring optimal safety, with ±0.5% DC V accuracy and wide 40Hz to 1kHz AC V bandwidth.

Key Features

  • Achieving a high level of safety in a compact body and lightweight design
  • Test leads conveniently wrap around the back
  • ±0.5% DC V basic accuracy, wide 40 Hz to 1 kHz AC V frequency characteristics
  • Low-pass filter (100 Hz/ 500 Hz) cuts high harmonics
  • Current measurement function eliminated to enhance safety
  • Broad -10 (14°F) to 50°C (122°F) operating temperature range
Need more information?

Please contact +6221-5467618, +6221-54212399 or email [email protected]

Specification

DT4251 DT4252 DT4253
Voltage AC V 4 ranges: 6.000V / 60.00V / 600.0V / 1000V
(Typical accuracy: ±0.9% rdg. ±3 dgt.)
DC V 5 ranges: 600.0mV / 6.000V / 60.00V / 600.0V / 1,000.0V
(Typical accuracy: ±0.3% rdg. ±5 dgt.)
High-precision
600mV range
n/a Yes (Accuracy: ±0.2% rdg. ±5 dgt.) n/a
Automatic AC/DC
voltage detection
Yes n/a Yes
Current DC mA, μA n/a n/a 4 ranges
60.00μA /
600.0μA /
6.000mA /
60.00mA
(Typical accuracy:
±0.8% rdg. ±5 dgt.)
AC A n/a 6.000A / 10.00A
(Typical accuracy:
±1.4% rdg. ± 3 dgt.)
n/a
DC A n/a 6.000A / 10.00A
(Typical accuracy:
±0.9% rdg. ± 5 dgt.)
n/a
Clamp 10A to 1000A
With clamp sensor
n/a 10A to 1000A
With clamp sensor*
Frequency 99.99Hz / 999.9Hz / 99.99kHz
(Typical accuracy: ±0.1% rdg. ±1 dgt.)
Resistance 6 ranges: 600.0Ω to 60.00MΩ
(Typical accuracy: ±0.7% rdg. ±5 dgt.)
Capacitance 4 ranges: 1.000μF to 10.00mF
(Typical accuracy: ±1.9% rdg. ± 5 dgt.)
Temperature n/a n/a Thermocouple
type: K*
Range: -40.0°C to 400.0°C
(Typical accuracy: ±0.5% rdg. ±2°C)
Continuity check Yes Yes Yes
Diode check Yes Yes Yes
Voltage detection Detection range:
80V AC to 600V AC
n/a n/a

Downloads