Hioki Memory HiLoggers are high-speed data loggers for recording multiple chanels of voltage, temperature, resistance, humidity, rotation, and pulse signals, providing complete isolation within channel sets. The 8423 with optional input modules log data at 10ms speeds across up to 600 simultaneously, and is configurable and controllable using a PC.

 

Need more information?

Please contact +6221-5467618, +6221-54212399 or email [email protected]

Specification

No. of connectable units Maximum 8 units (total 120 channels), Bundle 8 Modules together to achieve a 120-channel System, Bundle 5 Systems together to enable a maximum of 600 channels of simultaneous recording
Measurement parameters
Model 8948
Voltage : ±150mV to ±100V, 1-5V f.s. 6 ranges, Max. resolution 5µV
Temperature (thermocouples) : -200°C to 2000°C (depend on the sensor), 3 range (K, E, J, T, N, W (Wre5-26), R, S, B), Max. resolution 0.01°C
Max. allowable input : DC 100V, Max. rated voltage between channels : 200 V DC, Max. rated voltage to earth : 600 V DC, AC
Measurement parameters
Model 8949
Voltage : ±150mV to ±60V, 1-5V f.s. 6 range, Max. resolution 5µV
Temperature (thermocouples) : -200°C to 2000°C (depend on the sensor), 3 range (K, E, J, T, N, W (Wre5-26), R, S, B), Max. resolution 0.01°C
Temperature (Resistance temperature sensor) : -200°C to 800°C, 3 range (Pt 100, JPt 100), Max. resolution 0.01°C
Humidity : 100% rh f.s., 5.0 to 95.0% rh (use with the 9701), resolution 0.1% rh
Max. allowable input : DC 60V, Max. rated voltage between channels : 120 V DC, Max. rated voltage to earth : 600 V DC, AC
Measurement parameters
Model 8996
Totalized pulses : 0 to 1000M pulse, 1 range (No-voltage ‘a’ contact, open collector or voltage input), Max. resolution 1 pulse
Rotation count : 0 to 5000/n (r/s) f.s. 1 range (No-voltage ‘a’ contact, open collector or voltage input), Resolution 1/n (r/s) Note: n = pulses per rotation (1 to 1,000)
Digital input : ON/OFF digital signal
Max. allowable input : DC 50V, Max. rated voltage between channels : 33V AC, 70V DC, Max. rated voltage to earth : 600 V DC, AC, (Upper limit voltage that does not cause damage when applied between CH-1 to CH-5 each channel and chassis, CH-6 to CH-10 each channel and chassis, CH-11 to CH-15 each channel and chassis, and between each UNITs), (common ground for CH-1 to CH-5, common ground for CH-6 to CH-10, common ground for CH-11 to CH-15)
Recording intervals 10ms to 1hr, 19 range (5s to 1hr when combined with humidity measurement), Dual sampling : Recording intervals can be specified for every input module (high-speed and low-speed)
Function Measurement data are saved to the CF Card in real time, Trigger function, Digital filter (Input unit), Alarm output (use with the ALARM UNIT 8997), Data acquisition is controlled by the PC data acquisition program, FTP server function, HTTP server function
Interface LAN : supports 100Base-TX, USB : Ver 2.0, mini-B receptacle, CF card slot
Power supply Using the AC ADAPTER 9418-15 /20 VA (when connected with 8 units), 12V Battery (voltage may range from -20% to +30%, Please contact HIOKI for connection cord).
Dimensions & Mass 67 mm (2.64 in) W × 133 mm (5.24 in) H × 125 mm (4.92 in) D, 600 g (21.2 oz) (main unit 8423 only)
Accessories Operating Manual ×1, Quick Start Manual ×1, AC ADAPTER 9418-15 ×1, USB cable ×1, Connection Plate ×1, CD-R (data collection software “LOGGER UTILITY”) ×1, Connector cover ×1, Ferrite clamp ×1