HIOKI – MR8880

Hioki Memory HiCorders are high-speed waveform monitoring and recording devices that can simultaneously measure multiple quick-changing phenomena due to complete isolation between channels and from each channel to the ground.

Hioki Memory HiCorders are high-speed waveform monitoring and recording devices that can simultaneously measure multiple quick-changing phenomena due to complete isolation between channels and from each channel to the ground. The MR8880 is a data acquisition (DAQ) recorder built in with 4 analog channels that can accept direct input of 600V, enabling measurements of 3-phase systems.

 

Need more information?

Please contact +6221-5467618, +6221-54212399 or email [email protected]

Specification

Measurement functionality • High-speed function (high-speed recording)
• Real-time function (real-time recording)
No. of input channels 4 channels of analog input + 8 channels of logic input (standard)
*Analog input channels are isolated from one another and other device circuitry. Logic input channels share a common ground with the device.
Max. sampling speed 1 MS/sec (1 μs period; all channels sampled simultaneously)
Internal memory capacity 14 bits × 1 Mword per channel (1 word = 2 bytes, not expandable)
External memory • CF card slot × 1 (up to 2 GB; supported formats: FAT/FAT32)
• USB memory × 1 (USB 2.0 Standard-A receptacle)
Communications interfaces USB 2.0 Mini-B receptacle × 1
Functionality: Device configuration and measurement using communications commands; transfer of files from CF/USB memory to a computer (USB drive mode)
Operating environment
(non-condensing)
• Operating temperature range: -10°C to 50°C
• Operating humidity range: 80% RH or less at -10°C to 40°C, 60% RH or less at 40°C to 45°C, 50% RH or less at 45°C to 50°C
• When powering the instrument with the Z1000 battery: 0°C to 40°C, 80% RH or less
• When charging the Z1000 battery: 10°C to 40°C, 80% RH or less
Storage environment (non-condensing) • Storage temperature range: -20°C to 60°C
• Storage humidity range: 80% RH or less at -20°C to 40°C, 60% RH or less at 40°C to 45°C, 50% RH or less at 45°C to 60°C
• Z1000 battery: -20°C to 40°C, 80% RH or less
Standard compliance • Safety: EN61010
• EMC: EN61326, EN61000-3-2, EN61000-3-3
• Vibration resistance: JIS D 1601, Type 1: passenger vehicles; conditions: equivalent to Type A
Charging function
(reference value at 23°C)
Charge time: Approx. 3 hours
(The charging function is activated by connecting the AC adapter while the BATTERY PACK Z1000 is attached to the instrument.)
External dimensions and weight
(including battery pack)
• Recorder only: Approx. 205 (W) × 199 (H) × 67 (D) mm, 1.76 kg
• With printer: Approx. 303 (W) × 199 (H) × 67 (D) mm, 2.26 kg

Downloads