SOLAR I-V allows both testing a single-phase (three-phase with optional MPP300) photovoltaic system and verifying I-V curve.

SOLAR I-V allows both testing a single-phase (three-phase with optional MPP300) photovoltaic system and verifying I-V curve. Thanks to remote unit SOLAR02, it is possible to test the system complying with the requirement of simultaneity as provided for by the reference standard. SOLAR02 is a datalogger which, synchronized with SOLAR I-V, acquires the data relevant to irradiation and temperature while tests carried out by SOLAR I-V are carried out.

For measuring I-V curve, SOLAR I-V manages an internal database of the modules, which can be updated at any time by the user by comparing the measured data with the rated values, thus allowing the immediate evaluation whether the string or the module fulfills the efficiency parameters declared by the manufacturer. Current and voltage measurement at modules/strings output is measured with the 4-terminal method, which allows extending possible measuring cables without considering any compensation of their resistance, thus obtaining always precise measurements. At the end of the test, the display of I-V curve on the screen is a clear indication about the compliance with the specifications declared by the panel manufacturer.

 

Need more information?

Please contact +6221-5467618, +6221-54212399 or email [email protected]

Specification

Detection of I-V curve on PV modules and strings 128 points
Quick IVCK test for measuring Voc and Isc on PV modules and strings
Single-phase/three-phase photvoltaic systems’ testing 1MPPT (3MPPT with MPP300)
Measurement of irradiation with reference cell
Use of remote unit SOLAR-02 with USB RF connection RF
Temperature measurement of cell and environment
Active P, Reactive Q, Apparent S Power/Energy only active P
Max number of simultaneously selectable parameters 9
Recording with selectable integration period 5s-60m
Indicative memory duration (in days @ PI=10min @ max number of parameters) 8
Summary table of main electric parameters
Measuring range of I-V curve / VOC-ISC 1000V / 15A
Measuring range for photovoltaic testing 1000VDC / 265VAC (Single-Phase)
Measurement category CAT III 300V
Backlit LCD display
Internal memory capacity 200 curves I-V 8 [email protected] PI=10 min
Provided PC interface with software for Windows
Integrated WiFi For data download onto the PC
Custom management of internal PV module database 30 internal, 30.000 on software
Auto power off
Indication of recording duration for photovoltaic testing
Help on line on the display
Size (LxWx H) (mm) 235x165x75
Weight in grams (batteries included) 1200

Normative

  •  CE MARK
  •  CEI 64-8 612.6.2
  •  EMC 2004/108/CE Directive
  •  LVD 2006/95/CE Directive
  •  Guida CEI 82-25
  •  IEC/EN60891
  •  IEC/EN 61010-1
  •  EMC: IEC/EN61326
  •  IEC/EN61187