Radiodetection – 3300

TDR Time Domain Reflectometer / Cable Test.

The 3300 TDR is a mid-spec Time Domain Reflectometer optimized for use on telecom cables with dual-channel capability.

3300 Dual-Input Mid-Spec TDR

TDR Time Domain Reflectometer / Cable Test.

The 3300 TDR is a mid-spec Time Domain Reflectometer optimized for use on telecom cables with dual-channel capability.

The 3.300 unit is a mid-spec TDR optimized for use on CATV cables. With dual input capability, rechargeable batteries and printer connectivity, the product provides a cost effective and easy to use unit for first line technicians. The unit combines Riser Bond ease of use and advanced features such as Range Plus and Super Store. It is designed with optimum flexibility and ease of use for the CATV field technician. Other benefits include measurement of Return Loss at the cursor position to provide a preview of a not so obvious fault and an Intermittent Fault Detection mode.

The 3.300 TDR is not suitable for use in Europe or Australia and some other jurisdictions, please contact Radiodetection for details.

3300 Feature

  • Ease of use
  • Field durability
  • SuperStore
  • Intermittent fault detection
Need more information?

Please contact +6221-5467618, +6221-54212399 or email [email protected]

Specification

Product specifications
Physical – Instrument Only: Height:
Width: Depth: Weight:
4.7 inches (120 mm).
9.5 inches (240 mm).
2.4 inches (60 mm).
2.75 pounds (1.2 kg).
Physical – Instrument
with Nylon Carrying Case
Height: Width: Depth: Weight:
6 inches (152 mm).
11 inches (280 mm).
4.5 inches (115 mm).
4.75 pounds (2.15 kg).
Environmental:
Operating Temperature: Storage Temperature: Humidity:
0º C to 50º C (32º F to 122º F).
-20º C to 60º C (-4º F to 140º F).
95% maximum relative, non-condensing.
Power:
Battery:
Charging Source: Operating Time:
Internal, rechargeable, 7.2 V Nickel metal hydride. External 12 VAC transformer, 1.3 A.
Greater than 10 hours, continuous, without backlight.
Display: 320 x 240 dot-matrix liquid crystal display with electroluminescent backlighting.
Horizontal Resolution: 1 foot (0.1 m) at any VOP.
Vertical Resolution: 14 bits with 203 dots displayed.
Vertical Sensitivity: Greater than 56 dB.
Output Signal: Pulse widths of 5, 25, 100 nsec, 1 usec.
Output Balance: Variable.
Distance Accuracy: ± 0.5 ft (0.15 m) plus ± 0.01% of reading.
Maximum Ranges: 63,700 ft (19.4 km) at 99% VOP.
38,600 ft (11.8 km) at 60% VOP.
Range varies with VOP. Maximum testable cable lengths varies with pulse width and cable type.
Input Protection: 400 V (AC+DC) from DC to 400 Hz, decreasing to 10 V at 1 MHz.
Velocity of Propagation: Two user-selectable display formats:
VOP (%) with 2 digit precision ranging from 30% to 99%
V/2 with 3 digit precision ranging from 45 to 148 in meters mode or from 148 to 487 in feet mode.
Waveform Storage: Standard: 6144 samples per waveform:
16 SUPER-STORE waveforms.
Noise Filters: Standard: 50/60Hz, 4x, 8x, 16x, 32x, 64x, 128x, Averaging,
Auto.
Standard Accessories: Operator’s manual, 12 VAC charger, nylon carrying
case, telco test leads.

Download

Accessory

Model 3200/3300

  • NiMH battery pack (61/160-0038-00)
  • Charger (060-0002-00)