TESTCONSULT – SLT2

SLT2 is a highly accurate and robust system that enables you to monitor static pile tests whilst also ensuring the safety of site operatives.

SLT2 is a highly accurate and robust system that enables you to monitor static pile tests whilst also ensuring the safety of site operatives.

Featuring a 25m cable, users are able to monitor safely and accurately from distance, eliminating the need for personnel to enter potentially dangerous testing zones.

The user friendly software allows operators to view data in real-time whilst plotting the load settlement data as the test progresses. Should the test be stopped for any reason, there are back up routines which enable testing to recommence without any loss of data.

Need more information?

Please contact +6221-5467618, +6221-54212399 or email [email protected]

Specification

SLT2 system specifications  
Acquisition unit
SLT2 system specifications  Features undefinedReal-time load and displacement display
Safe and automatic logging of data
Rugged site suitable transducers
ASCII output of data
Automatic report generation
SLT2 system specifications  Acquisition unit undefined8 channel DAQ unit
SLT2 system specifications  Data storage undefinedData files are stored to the connected PC as the test proceeds and includes real-time, elapsed time, load, 4No displacement readings, average settlement and rate of settlement
Full header information is also stored including site, job number, weather. operator, pile number, pile diameter, pile type, working load, max test load, date and start time
SLT2 system specifications  Dimensions undefinedL 218mm x W 187mm x D 55mm
SLT2 system specifications  Weight undefinedApprox 6Kg
SLT2 system specifications  Connectors undefinedWaterproof Mil spec and rugged Jaeger type, each uniquely marked
SLT2 system specifications  Power undefined110/250VAC inputs – can be battery powered by 12VDC/250VAC power converter which can also power site PC
SLT2 system specifications  Displacement transducer type undefined4No linear potentiometer
SLT2 system specifications  Displacement transducer range undefined0-100mm
SLT2 system specifications  Displacement transducer resolution undefined0.01mm
SLT2 system specifications  Load cell type undefinedStainless steel, non-indicating compression type, IP68 protected
SLT2 system specifications  Load cell range undefined25 to 1000 Te
SLT2 system specifications  Operating temperature  undefined-20°C to +65°C
SLT2 system specifications  Accuracy undefined± 0.3% of applied load
SLT2 system specifications  Pressure transducer (optional) undefined0-700Bar, IP67 protection, 0.25% accuracy, operating temperature range -20°C to +65°C
SLT2 system specifications  Real-time display undefined

Average settlement v load curve
Settlement for each displacement transducer
Load
Rate of settlement

SLT2 system specifications  Print display undefinedTable: Time, elapsed time, displacements, load and settlement rate
Graph: Applied load v settlement
Graph: Applied load and settlement v time

Downloads