Housed in a robust safety case the 5080 is easily portable and ideal for field calibration work. It is battery powered, which ensures isolation and prevents inaccuracies due to stray leakage. Features include safety interlock that prevents contact with earth bond studs during insulation and leakage tests, and an LCD display for voltage and current.

Need more information?

Please contact +6221-5467618, +6221-54212399 or email [email protected]

Specification

Technical Specifications

Earth Bond: Calibrated low value resistive loads
Values / Accuracy 20mΩ, accuracy 5%
190mΩ, 210mΩ, 950mΩ, 1.050mΩ, 1.08Ω, 2Ω, 10Ω, 18Ω, accuracy 1%
Open circuit voltage measurement Range: 0 to 20V
Accuracy: 0.25% of full scale
High current AC measurement Range: 0 to 50A AC
Accuracy: 0.5% of reading +/- 0.2A
Low current AC measurement Range: 0 to 2A AC
Accuracy: 0.5% of reading +/- 2mA
Low current DC measurement Range: 0 to 2A DC
Accuracy: 1% of reading +/- 2mA

 

Insulation: Calibrated high value resistive loads
Values / Accuracy 95kΩ, 105kΩ, 500kΩ, 950kΩ, 1.05MΩ, 5MΩ, 10MΩ, accuracy 0.1%
20MΩ, 50MΩ, 100MΩ, accuracy 1.0%
Open circuit voltage measurement Range: 0 to 1kV DC
Accuracy: 0.25% of full scale
Current measurement Range: 0 to 20mA DC. Accuracy: 0.25% of full scale

 

Leakage: Resistive loads for leakage current
Nominal Leakage Currents At 230V AC of 0.5, 1, 2, 5, 10, 15mA
Mains voltage measurement Range: 0 to 500V AC
Accuracy 0.25% of full scale
Leakage current measurement Range: 0 to 20mA AC
Accuracy 0.25% of full scale

 

Touch Leakage: Constant current source for touch leakage meters
Current 1.9mA AC 50 +/-5 Hz, into 2K2 maximum load resistance
Current measurement Range: 0 to 2mA AC. Accuracy: 0.25% of full scale

 

Load Test: Connection of external load via an IEC connector
Mains voltage measurement Range: 0 to 500V AC
Accuracy: 0.25% of full scale
Load current measurement Range: 0 to 13A AC
Accuracy: 0.5% of full scale

General Specifications

Power Internal battery 6V re-chargeable NiCad, >200 hrs between charges.
Dimensions W406 x H175 x D330mm
Weight 5.5kg
Supplied With 4mm terminal box adaptor, 110V adaptor, IEC connector (for external load), battery charger, and user manual.
Optional Extras Calibration certificates traceable NPL and UKAS
Country of Origin UK