TROTEC – DL200L

As well as offering all sensor functionality and equipment of the DL200H, the DL200L also provides an additional NDIR sensor for detecting concentrations of CO₂ in the room air.

As well as offering all sensor functionality and equipment of the DL200H, the DL200L also provides an additional NDIR sensor for detecting concentrations of CO₂ in the room air.

For long term logging of environmental data and carbon dioxide values, the DL200L, with its alarm function, is the ideal air controlling instrument for workspaces, for example, in schools, public authorities and businesses.

Definition of measurement channel – How many measured values can be recorded?

All devices from the DL series are powerful multi-channel data loggers with which you can not only detect, but also record all of the compatible measured values (see technical specifications).

The term “measurement channel” is not used to mean the same as it is by some of our competitors – meaning the available sensors, but instead – the same as in analysis software – it means one individually selectable “recording track”, i.e. the value which should be logged.

For each measured value and measured unit (channel group), one or more of the four following types of measured values can be recorded: current, minimum, maximum or average. Each of these four values represents a measurement channel.

The maximum amount of available measurement channels for each data logger is thus the amount of detectable channel groups (e.g. temperature in °C) multiplied by the four types of measured values.

In total, 20 of these measurement channels can be freely selected for logging and three for being displayed.

A few practical benefits:

  • Maintenance-free high quality measuring device “made in Germany”
  • Tamper-proof measured value detection and documentation
  • Perfect for measuring over a long period
  • Storage for up to 3,200,000 measured values
  • Simultaneous recording of up to
  • 20 separate measurement channels
  • Network function
  • Low energy consumption
  • Flexible power supply via batteries or USB – or optionally with PoE, also via LAN
  • Timer function, variable measurement intervals, alarm function for each measurement channel
  • Three-row LCD for measurement value display
  • Including professional software
Need more information?

Please contact +6221-5467618, +6221-54212399 or email [email protected]

Specification

Technical data
Master data
  Article number 3.510.260.013
Air temperature
  Measuring principle NTC
  Measuring range [°C] -20 – 50
  Accuracy [°C] ±0.3 (0 – 40), else 0.5
  Display resolution [°C] 0,1
Relative humidity
  Measuring principle capacitive
  Measuring range [% RH] 10 – 95
  Accuracy [% RH] ±2
  Display resolution [% RH] 0,5
Air pressure
  Measuring principle
  Measuring range [hPa]
  Accuracy [hPa]
  Display resolution [hPa]
CO₂ concentration
  Measuring principle NDIR
  Measuring range [ppm] 0 – 5,000
  Accuracy ± 50 ppm / + 3 % of measured value (at 20 °C and 1,013 mbar)
  Display resolution [ppm] 1
  Long-term stability [ppm/a] 20
Voltage input
  Min. measuring range [V]
  Max. measuring range [V]
  Accuracy [µV]
  Accuracy [%] of the measured value
  Resolution
Voltage measurement
  Min. measuring range [mA] in two-wire operation
  Max. measuring range [mA] in two-wire operation
  Min. measuring range [mA] in three-wire operation
  Max. measuring range [mA] in three-wire operation
  Accuracy [µA]
  Accuracy [%] of the measured value
  Resolution [µA]
  Output load [Ω]
Thermal element K
  Min. measuring range [°C]
  Max. measuring range [°C]
  Accuracy between -200 °C … 0 °C [°C]
  Accuracy between -200 °C … 0 °C [%] of the measured value
  Accuracy between 0 °C … 1,200 °C [°C]
  Accuracy between 0 °C … 1,200 °C [%] of the measured value
  Resolution [°C]
Thermal element J
  Min. measuring range [°C]
  Max. measuring range [°C]
  Accuracy between -200 °C … 0 °C [°C]
  Accuracy between -200 °C … 0 °C [%] of the measured value
  Accuracy between 0 °C … 1,200 °C [°C]
  Accuracy between 0 °C … 1,200 °C [%] of the measured value
  Resolution [°C]
Thermal element S
  Min. measuring range [°C]
  Max. measuring range [°C]
  Accuracy between -50 °C … 0 °C [°C]
  Accuracy between -50 °C … 0 °C [%] of the measured value
  Accuracy between 0 °C … 1,700 °C [°C]
  Accuracy between 0 °C … 1,700 °C [%] of the measured value
  Resolution [°C]
Pt100
  Min. measuring range [°C]
  Max. measuring range [°C]
  Accuracy [°C]
  Accuracy [%] of the measured value
  Resolution [°C]
Interfaces
  LAN
  Plug socket
  BNC
  RS-485
  10-pin terminal
  USB
Power supply
  Internal (battery) 4 x LR6 AA mignon battery, operating hour > 1 year (depending on sensors and configuration)
  External (USB)
  External via LAN (PoE model)
  Terminals for external power supply to supply the sensor
Display
  Dimensions [mm] 90 x 64
  LCD
Memory organization
  Sensing interval 10/30 s, 1/10/12/15/30 min, 1/3/6/12/24 h
  Saving interval 1/10/12/15/30 min
  Memory 16 MB, 3,200,000 measured values
  Data logging up to 20 measuring channels parallel
  Available measurement channels 28
  Available channel groups 7
Housing design
  Plastic
Weight (packing excluded)
  Weight [kg] 0,250
Dimensions (packing excluded)
  Length [mm] 166
  Width [mm] 32
  Height [mm] 78
Standard scope of delivery
Battery(-ies)
  Option
USB connection cable
  Option
CD-Rom with Smartgraph PC software and operating manual
  Option
Ascertainable measured values and functions
Internal sensors
  Air temperature [°C]
  Air temperature [°F]
  Relative humidity [%]
  Absolute humidity [g/m³]
  Dew point temperature [°C]
  Dew point temperature [°F]
  Relative air pressure [hPa]
  Absolute air pressure [hPa]
  CO₂ -concentration [ppm]
External sensors
  CO₂ -concentration [ppm]
  Surface temperature [°C]
  Surface temperature [°F]
  Material temperature [°C]
  Material temperature [°F]
  Air temperature [°C]
  Air temperature [°F]
  Wood moisture [digits]
  Building moisture [digits]
  Relative humidity [%]
  Absolute humidity [g/m³]
  Dew point temperature [°C]
  Dew point temperature [°F]
  Battery voltage [mV, V]
  Voltage [mV, V]
  Current [mA, A]
  Absolute air pressure [hPa, Pa]
  Relative air pressure [hPa, Pa]
  Differential pressure [Pa]
  Flow rate [m/s]
  Mixing ratio [g/kg dry air]
  Particle concentration [0.1 µm]
  Particle concentration [0.2 µm]
  Particle concentration [0.3 µm]
  Particle concentration [0.5 µm]
  Particle concentration [1 µm]
  Particle concentration [5
  Particle concentration [10
  Particle concentration [x µm]
  Particle concentration [y µm]
  Particle concentration [z µm]
  Unknown
  Inactive
  Cooling limit temperature [°C]
  Cooling limit temperature [°F]
  Global radiation [W/m²]
  Daylight
  Amount of precipitation [l/m²]
  Wind speed [m/s]
  Wind direction
  Ground dampness
  Leaf wetness