TROTEC – DL200X

Whether particle concentration, pressure, conveyor speed or flow rate, the DL200X can be configured for any requirement you may have, because instead of relying on internal sensors, it uses external connections for digital and analogue sensors.

Whether particle concentration, pressure, conveyor speed or flow rate, the DL200X can be configured for any requirement you may have, because instead of relying on internal sensors, it uses external connections for digital and analogue sensors.

Using an RS485 interface, up to four intelligent bus sensors can be built in, for example, particle counters or temperature-dampness sensors for cleanrooms.

Additionally, the DL200X has a 10 pin terminal, where two other analogue sensors can be attached to, for example, Pt100 temperature sensors, thermal elements (K, J, S type) or voltage and current sensors with the standardised signal for individual measurement transducer in various physical sizes and units.

At maximum configuration, six different sensors can run at the DL200X simultaneously, while universal measuring networks can operate in real time due to the device’s LAN capability.

Definition of measurement channel

How many measured values can be recorded?
All devices from the DL series are powerful multi-channel data loggers with which you can not only detect, but also record all of the compatible measured values (see technical specifications).

The term “measurement channel” is not used to mean the same as it is by some of our competitors – meaning the available sensors, but instead – the same as in analysis software – it means one individually selectable “recording track”, i.e. the value which should be logged.

For each measured value and measured unit (channel group), one or more of the four following types of measured values can be recorded: current, minimum, maximum or average. Each of these four values represents a measurement channel.

The maximum amount of available measurement channels for each data logger is thus the amount of detectable channel groups (e.g. temperature in °C) multiplied by the four types of measured values.

In total, 20 of these measurement channels can be freely selected for logging and three for being displayed.

Practical benefits

  • Maintenance-free high quality measuring device “made in Germany”
  • Tamper-proof measured value detection and documentation
  • Perfect for measuring over a long period
  • Storage for up to 3,200,000 measured values
  • Simultaneous recording of up to
  • 20 separate measurement channels
  • Network function
  • Low energy consumption
  • Flexible power supply via batteries or USB – or optionally with PoE, also via LAN
  • Timer function, variable measurement intervals, alarm function for each measurement channel
  • Three-row LCD for measurement value display
  • Including professional software
Need more information?

Please contact +6221-5467618, +6221-54212399 or email [email protected]

Specification

Technical data
Master data
Article number 3.510.260.014
Air temperature
Measuring principle
Measuring range [°C]
Accuracy [°C]
Display resolution [°C]
Relative humidity
Measuring principle
Measuring range [% RH]
Accuracy [% RH]
Display resolution [% RH]
Air pressure
Measuring principle
Measuring range [hPa]
Accuracy [hPa]
Display resolution [hPa]
CO₂ concentration
Measuring principle
Measuring range [ppm]
Accuracy
Display resolution [ppm]
Long-term stability [ppm/a]
Voltage input
Min. measuring range [V] 0
Max. measuring range [V] 1
Accuracy [µV] ± 200
Accuracy [%] of the measured value ± 1
Resolution < 500 µV
Voltage measurement
Min. measuring range [mA] in two-wire operation 4
Max. measuring range [mA] in two-wire operation 20
Min. measuring range [mA] in three-wire operation 0
Max. measuring range [mA] in three-wire operation 20
Accuracy [µA] ± 4
Accuracy [%] of the measured value ± 0,1
Resolution [µA] < 5
Output load [Ω] ca. 50
Thermal element K
Min. measuring range [°C] -200
Max. measuring range [°C] 1.200
Accuracy between -200 °C … 0 °C [°C] ± 1
Accuracy between -200 °C … 0 °C [%] of the measured value ± 0,5
Accuracy between 0 °C … 1,200 °C [°C] 0
Accuracy between 0 °C … 1,200 °C [%] of the measured value ± 0,2
Resolution [°C] < 0,2
Thermal element J
Min. measuring range [°C] -200
Max. measuring range [°C] 1.200
Accuracy between -200 °C … 0 °C [°C] ± 1
Accuracy between -200 °C … 0 °C [%] of the measured value 0,5
Accuracy between 0 °C … 1,200 °C [°C] 0
Accuracy between 0 °C … 1,200 °C [%] of the measured value ± 0,2
Resolution [°C] < 0,2
Thermal element S
Min. measuring range [°C] -50
Max. measuring range [°C] 1.700
Accuracy between -50 °C … 0 °C [°C] ± 1
Accuracy between -50 °C … 0 °C [%] of the measured value 0,5
Accuracy between 0 °C … 1,700 °C [°C] ± 1
Accuracy between 0 °C … 1,700 °C [%] of the measured value ± 0,2
Resolution [°C] < 0,2
Pt100
Min. measuring range [°C] -200
Max. measuring range [°C] 500
Accuracy [°C] ± 0,2
Accuracy [%] of the measured value ± 1
Resolution [°C] < 0,02
Interfaces
LAN
Plug socket
BNC
RS-485
10-pin terminal
USB
Power supply
Internal (battery)
External (USB)
External via LAN (PoE model)
Terminals for external power supply to supply the sensor
Display
Dimensions [mm] 90 x 64
LCD
Memory organization
Sensing interval 10/30 s, 1/10/12/15/30 min, 1/3/6/12/24 h
Saving interval 1/10/12/15/30 min, 1/3/6/12/24 h
Memory 16 MB, 3,200,000 measured values
Data logging up to 20 measuring channels parallel
Available measurement channels max. 128
Available channel groups max. 32
Housing design
Plastic
Weight (packing excluded)
Weight [kg] 0,250
Dimensions (packing excluded)
Length [mm] 166
Width [mm] 32
Height [mm] 78
Standard scope of delivery
Battery(-ies)
  Option
USB connection cable
  Option
CD-Rom with Smartgraph PC software and operating manual
  Option
Ascertainable measured values and functions
Internal sensors
  Air temperature [°C]
  Air temperature [°F]
  Relative humidity [%]
  Absolute humidity [g/m³]
  Dew point temperature [°C]
  Dew point temperature [°F]
  Relative air pressure [hPa]
  Absolute air pressure [hPa]
  CO₂ -concentration [ppm]
External sensors
  CO₂ -concentration [ppm]
  Surface temperature [°C]
  Surface temperature [°F]
  Material temperature [°C]
  Material temperature [°F]
  Air temperature [°C]
  Air temperature [°F]
  Wood moisture [digits]
  Building moisture [digits]
  Relative humidity [%]
  Absolute humidity [g/m³]
  Dew point temperature [°C]
  Dew point temperature [°F]
  Battery voltage [mV, V]
  Voltage [mV, V]
  Current [mA, A]
  Absolute air pressure [hPa, Pa]
  Relative air pressure [hPa, Pa]
  Differential pressure [Pa]
  Flow rate [m/s]
  Mixing ratio [g/kg dry air]
  Particle concentration [0.1 µm]
  Particle concentration [0.2 µm]
  Particle concentration [0.3 µm]
  Particle concentration [0.5 µm]
  Particle concentration [1 µm]
  Particle concentration [5
  Particle concentration [10
  Particle concentration [x µm]
  Particle concentration [y µm]
  Particle concentration [z µm]
  Unknown
  Inactive
  Cooling limit temperature [°C]
  Cooling limit temperature [°F]
  Global radiation [W/m²]
  Daylight
  Amount of precipitation [l/m²]
  Wind speed [m/s]
  Wind direction
  Ground dampness
  Leaf wetness

Download