YAMADEN – FXD

Explosion – proof level meter. Corresponds to a wide range of measured objects, and also supports changes in electrical properties.

Float type level gauge of explosion-proof structure inherits as it is a high-function of FXL

  • It is possible to measure the level of the liquid level stably even in an environment of explosive atmosphere.
  • It is a flameproof explosion-proof level meter that inherited the abundant functions of the FXL series.
  • It also supports changes in electrical properties of the object to be measured.
      ■ It is a product of pressure-resistant explosion-proof standard (Exd II BT 4).
    ■ It can be used with simple initial setting (one touch push button).
    ■ The dead zone can be greatly reduced, and it is possible to measure with a wide range of sensors.
We also have a special type for measuring the liquid level inside the glass gauge attached to a glass gauge.
Need more information?

Please contact +6221-5467618, +6221-54212399 or email [email protected]

Features

1. corresponds to the wide range of the object to be measured
does not affect the electrical properties change of the object to be measured. It is not affected by temperature inside the tank, pressure, gas components.

2. safe design withstand the harsh tank conditions
waterproof housing (protection class IP65), the detection part of the pressure-resistant 1Mpa, corresponding to various use conditions, such as heat-resistant 100 ℃.

3. simple configuration can be used in
it can be measured with a simple initial setup (one-touch push-button). The undetectable part can be greatly reduced, and it can be measured in a wide range of degrees of freedom.

4. Equipped with each function for stable measurement
standard equipment such as a delay setting function and the watchdog function.

Achievements

Use  Remaining amount measurement (level meter / level meter)
Measured object  Liquid / bubble neglect
Detailed measurement item  Distilled water / Distilled water / Alcohol / Pure water, Ultrapure water / Cleaning fluid / Oil (non-explosion) Work oil / Oil (Explosion proof) Fuel tank, Kerosene / Waste liquid / Foam detection, Foam neglect detection
Contact / non-contact  contact
Measuring method  Float type
Explosion proof  Explosion proof
Tank size  Medium size (drum size)
Mounting position  Vertical (from above)
Detailed measurement environment  Water supply control to elevated tanks such as buildings and condominiums, drainage control of drain tanks / raw material level control / underground pits / wide liquids (even when the type of liquid changes or the electric properties of liquid changes) Possible) / water level monitoring of water supply and sewerage

Specification

Amplifier section

Power supply AC / DC 20 to 250 V
Power consumption 1.5 VA or less
Operating ambient temperature -10 ° C to + 60 ° C
output 4.0 mA output for 0% stored value, 20.0 mA output for 100% stored value, output limit 0.02 mA (about -25%) to 20.46 mA (about 102%), 4 to 20 mA (maximum load 500 Ω or less)
Response speed (delay) About 0.5 to 180 seconds variable
Protection grade IP20
Wiring port Dedicated cable gland (Applicable cable diameter φ 10 to 12 mm, φ 7.5 to 10 mm)
weight Approx. 800 g (Only amplifier part, electrode and cable not included)
Wiring cable FXD is a separate type, but dedicated cable is not required. Please use a cable with 4 cores, 0.5 sq or more (max 500 m) for wiring between the amplifier and the electrode.
Explosion-proof standard Explosion proof construction (Exd II BT 4)
option RS485 communication

Connection

Size JIS 5K 50 A FF (It can be changed by request)
Material SUS 304 (option SUS 316)

float

Outer Diameter Φ 50 × H 48
Material SUS 304 (option SUS 316)
Specific gravity of measurable liquid 0.55 or more

Stem

Outer Diameter Φ 13 mm
Material SUS 304 (option SUS 316)
L dimension (max) Maximum 3000 mm ※ It may be shorter depending on usage environment. For actual maximum dimensions, please contact our sales representative.

Float Other

Allowable temperature -10 ° C to + 100 ° C
Detection pitch Maximum 8 mm
Dead zone With a specific gravity of 0.55 Stem tip 57 mm and case side 1 mm Specific gravity 1.0 When stem tip 36 mm and case side 22 mm
Allowable pressure 1 MPa * Depending on the withstand pressure of the connection part when the connection part withstand voltage is below this value.
Protection grade IP65