YAMADEN – FXL Series

A liquid level gauge realizing miniaturization and multiple functions. It also supports a wide range of measured objects and changes in electrical properties.

Float type liquid level gauge realizing miniaturization and multiple functions

  • Wide range corresponds to the measured object
    electrical properties of, liquid will also correspond to the case of change.
  • Stable liquid level measurement is possible even under severe conditions.
    ■ It can be used with simple initial setting (one touch push button).
    ■ The dead zone can be greatly reduced, and it is possible to measure with a wide range of sensors.
Line up according to specifications such as standard flange connection, helir connection, thread connection connection etc. are available.
Need more information?

Please contact +6221-5467618, +6221-54212399 or email [email protected]

Features

1. corresponds to the wide range of the object to be measured
does not affect the electrical properties change of the object to be measured. It is not affected by temperature inside the tank, pressure, gas components.

2. safe design withstand the harsh tank conditions
waterproof housing (protection class IP68), the detection part of the pressure-resistant 1Mpa, corresponding to various use conditions, such as heat-resistant 100 ℃.

3. simple configuration can be used in
it can be measured with a simple initial setup (one-touch push-button). The undetectable part can be greatly reduced, and it can be measured in a wide range of degrees of freedom.

4. Equipped with each function for stable measurement
standard equipment such as a delay setting function and the watchdog function.

Achievements

Use  Remaining amount measurement (level meter / level meter)
Measured object  Liquid / bubble neglect
Detailed measurement item  Distilled water / Distilled water / Alcohol / Pure water, Ultrapure water / Cleaning fluid / Oil (non-explosion) Working oil / Waste liquid / Foam detection, Foam neglect detection
Contact / non-contact  contact
Measuring method  Float type
Explosion proof  None (non-explosion-proof)
Tank size  Medium size (drum size)
Mounting position  Vertical (from above)
Detailed measurement environment  Water supply control to elevated tanks such as buildings and condominiums, drainage control of drain tanks / raw material level control / underground pits / wide liquids (even when the type of liquid changes or the electric properties of liquid changes) Possible) / water level monitoring of water supply and sewerage

Specification

Amplifier section

Power supply AC / DC 20 to 250 V
Power consumption 1.5 VA or less
Operating ambient temperature -10 ° C to + 60 ° C
output 4.0 mA output for 0% stored value, 20.0 mA output for 100% stored value, output limit 0.02 mA (about -25%) to 20.46 mA (about 102%), 4 to 20 mA (maximum load 500 Ω or less)
Measurement accuracy ± 8 mm
Response speed (delay) About 0.5 to 180 seconds variable
Wiring port G1 / 2
weight Approx. 800 g (Only amplifier part, electrode and cable not included)
option RS-485 communication

Sensor part

Model Standard flange type FXL-13N1-R1110JH1 Standard Helier type FXL-13N1-R1110DR1 Standard thread-in type FXL-13N1-R1110RH1
Material SUS 304 SUS 304 SUS 304
Allowable temperature -10 ° C to + 80 ° C -10 ° C to + 80 ° C -10 ° C to + 80 ° C
Allowable pressure 1 MPa 1 MPa 1 MPa
Protection grade IP68 IP68 IP68

Connection

Model Standard flange type FXL-13N1-R1110JH1 Standard Helier type FXL-13N1-R1110DR1 Standard thread-in type FXL-13N1-R1110RH1
Size JIS 5K 50 A FF (Can be changed) IDF / ISO 2.5S (changeable) R2 (It is changeable)
Material SUS 304 (option SUS 316) SUS 304 (option SUS 316) SUS 304 (option SUS 316)

float

Model Standard flange type FXL-13N1-R1110JH1 Standard Helier type FXL-13N1-R1110DR1 Standard thread-in type FXL-13N1-R1110RH1
Outer Diameter Φ 50 × H 48 Φ 50 × H 48 Φ 50 × H 48
Material SUS 304 (option SUS 316) SUS 304 (option SUS 316) SUS 304 (option SUS 316)
Specific gravity of measurable liquid 0.55 or more 0.55 or more 0.55 or more

Stem

Model Standard flange type FXL-13N1-R1110JH1 Standard Helier type FXL-13N1-R1110DR1 Standard thread-in type FXL-13N1-R1110RH1
Outer Diameter Φ 13 mm Φ 13 mm Φ 13 mm
Material SUS 304 (option SUS 316) SUS 304 (option SUS 316) SUS 304 (option SUS 316)
L dimension (max) Up to 3000 mm Up to 3000 mm Up to 3000 mm

Float Other

Model Standard flange type FXL-13N1-R1110JH1 Standard Helier type FXL-13N1-R1110DR1 Standard thread-in type FXL-13N1-R1110RH1
Allowable temperature -10 ° C to + 80 ° C -10 ° C to + 80 ° C -10 ° C to + 80 ° C
Detection pitch Maximum 8 mm Maximum 8 mm Maximum 8 mm
Dead zone With a specific gravity of 0.55 Stem tip 57 mm and case side 1 mm Specific gravity 1.0 When stem tip 36 mm and case side 22 mm With a specific gravity of 0.55 Stem tip 57 mm and case side 1 mm Specific gravity 1.0 When stem tip 36 mm and case side 22 mm With a specific gravity of 0.55 Stem tip 57 mm and case side 1 mm Specific gravity 1.0 When stem tip 36 mm and case side 22 mm
Allowable pressure 1 MPa * Depending on the withstand pressure of the connection part when the connection part withstand voltage is below this value. 1 MPa * Depending on the withstand pressure of the connection part when the connection part withstand voltage is below this value. 1 MPa * Depending on the withstand pressure of the connection part when the connection part withstand voltage is below this value.
Protection grade IP68 IP68 IP68
option The connection part can be changed, the material can be changed (SUS 316), wave barrier, oil proof treatment, electrolytic polishing, buffing finish (# 400) The connection part can be changed, the material can be changed (SUS 316), wave barrier, oil proof treatment, electrolytic polishing, buffing finish (# 400) The connection part can be changed, the material can be changed (SUS 316), wave barrier, oil proof treatment, electrolytic polishing, buffing finish (# 400)