YAMADEN – YF – GS □ S

Multiple point (1 to 4 points) liquid level detection is possible with one unit. High temperature specification, also correspond to explosion-proof specifications.

Multi-point (1-4 points) detectable SUS made small float-type level switch

  • Small float switch without terminal box.
  • Multiple point (1 to 4 points) liquid level detection is possible.
    ■ Combined with the relay barrier also supports intrinsically safe explosion protection.

By the vertical mounting and horizontal mounting, you can choose two types of the following

  • YF-GS □ S type 🙁 vertical mounting) liquid level detection can be up to a maximum of 4 points

other, special specification, also corresponds to the high-pressure specifications, offers, such as explosion-proof.

Need more information?

Please contact +6221-5467618, +6221-54212399 or email [email protected]

Features

1. by the vertical mounting and horizontal mounting, you can choose two types of following
vertical mounting type: up to 4-point liquid level detection possible ⇒ YF-GS □ S type
Horizontal mounting type: liquid level detection can be up to 2 points ⇒ YF- GS □ L type

2. It is durability and reliability
temperature, humidity, not affected by the gas, and the like.

3. You can select the material and structure in the nature or conditions of use of the corresponding measurement liquid
oil-free processing, electrolytic polishing, buff finish (# 400), such as bonding (between the float stem connection)

4. nature in combination with the relay barrier Corresponds to safety explosion-proof structure

Achievements

Use  Level detection (level switch)
Measured object  Liquid / bubble neglect
Detailed measurement item  Multiple point detection (general water purification, sewage, distilled water, salt water, acidic chemical liquid, alkaline chemical liquid etc) / oil (non-explosion-proof) of tap water, distilled water / alcohol / pure water, ultra pure water / cleaning liquid / Oil / oil (explosion-proof) fuel tank, kerosene / liquid waste / bubble detection, bubble neglect detection
Contact / non-contact  contact
Measuring method  Float type
Explosion proof  None (non-explosion-proof) / intrinsically safe explosion
Tank size  Compact (small container size)
Mounting position  Vertical (from the top) / Horizontal (from the side)
Detailed measurement environment  Multi-point liquid level control / Water supply control to elevated water tanks such as buildings and condominiums, drainage control of drain tank / raw material level control / wide liquid (change in liquid type, change in electric properties of liquid Can measure even) / Water level monitoring of water supply and sewerage

Specification

Connection

Size G1 / 8
Material SUS 304

float

Outer Diameter Φ 28 × H 27
Material SUS 304
Specific gravity of measurable liquid 0.7 or more

Stem

Outer Diameter Φ 8 (Φ 9 in case of 4 contacts)
Material SUS 304
L dimension (max) 1000 mm
option The material can be changed. (SUS 316)

Electric rating

Contact capacity DC 50 W / AC 70 VA
Maximum switching voltage 350 V DC, 300 V AC
Maximum switching current DC 0.7 A / AC 0.5 A

Float Other

Maximum detection point Four
Allowable temperature -10 ° C. to + 100 ° C. (180 ° C.)
Ln dimension (min) 25 mm
L dimension (min) 55 mm
Set interval size (min) 35 mm
L – Ln size (min) 30 mm
option No oil treatment, electrolytic polishing, buff finish (# 400), bonding (float to stem connection