SCR ELEKTRONIKS – 3 Station MCB

“To verify the 28 Days Test (21 hr ON, 3 hr OFF Test) as per clause 9.9 of IEC 60898-1”

“To verify the 28 Days Test (21 hr ON, 3 hr OFF Test) as per clause 9.9 of IEC 60898-1”

Stand alone unit after initial configuration of test parameters: The panel is capable to generate accurate test results for a continuous period of 28 days as required in the 28 days test

Cooling shall be provided by means of optimally placed Exhaust fans distributed all over to remove the hot air generated inside the panel cabinet

Power Loss Measurement available as an extra feature
Single / Three Phase operation possible
Servo controlled mechanism to control current (+/- 1%) against incoming fluctuations

Need more information?

Please contact +6221-5467618, +6221-54212399 or email [email protected]

Specification

  • Total current range 0 to 200 A

  • 0.5A to 125A at 30V open circuit Voltage CT range 2A, 5A, 10A, 25A, 50A, 100A,200A

  • 50 / 60 Hz operation as per incoming line frequency

  • Overall accuracy of the panel is better than class 1.0

  • Digital Temperature Indicator with input from thermocouple

  • Digital Volt Meter with 5 ranges (200mV, 2V, 20V, 200V, 250V) to measure open circuit voltage & mV drop across MCB

  • Digital Ammeter with CT (Indication on servo controller)

Downloads