SCR ELEKTRONIKS – MCCB Overload Trip

Available in multi-pole testing options
Available in 1,2,3,4 testing stations

Available in multi-pole testing options
Available in 1,2,3,4 testing stations
Available in Manual as well as PC based option
Drop down menu in the software to once select the type (rating or calibre) of MCCB: Rest of the test parameters get selected automatically (User can simply jump from one type of MCCB to other instantaneously)
IEC based test parameters automatically configured
Software: NI LabVIEW based for user interface, settings selection, process control & report generation
Debug / Diagnostic Mode in the software
Servo Controlled Voltage Regulation ensures stable voltage at the output

Need more information?

Please contact +6221-5467618, +6221-54212399 or email [email protected]tridinamika.com

Specification

  • 440 V, 3 phase, 50 Hz input
  • Number of Stations 1 to 4: User specified
  • Output current programmable up to 8000 A (Economical Variants available for maximum continuous current less than 8000 A: User can customize the parameter) at a conveniently low voltage
  • Can test MCCBs of different ratings and different number of poles on a single bench
  • Test Procedure options: IEC 60947-2 / customized
  • Pressure Required for pneumatic handling: Approximately 8-12 Bar depending on the MCCB size
  • IBM PC / compatible make with NI LabVIEW based TestwareTM
  • 500 VA branded UPS

Downloads