The PSW-Series is a single-output multi-range programmable switching DC Power Supply covering a power range up to 1080W.

The PSW-Series is a single-output multi-range programmable switching DC Power Supply covering a power range up to 1080W. This series of products include fifteen models with the combination of 30V, 80V, 160V, 250V, and 800V rated voltages and 360W, 720W and 1080W maximum output powers. The multi-range feature allows the flexible and efficient configuration of voltage and current within the rated power range. As the PSW-Series can be connected in series for maximum 2 units or in parallel for maximum 3 units, the capability of connecting multiple PSW units for higher voltage or higher current output provides a broad coverage of applications. With the flexibility of multi-range power utilization and series/parallel connection, the PSW Series significantly reduces the user’s investment for various power supply products to accommodate the projects with different power requirements.

The CV/CC priority selection of the PSW-Series is a very useful feature for DUT protection. The conventional power supply normally operates under CV mode when the power output is turned on. This could bring a high inrush current to the capacitive load or current-intensive load at the power output-on stage. Taking the I-V curve verification of LED as an example, it becomes a very challenging task to perform this measurement using a conventional power supply. With LED connected to a power supply under CV mode as the initial setting, when the power output is turned on and the voltage rises to the LED forward voltage, the current will suddenly peak up and exceed the preset value of current limit. Upon detecting this high current, the power supply starts the transition from CV mode to CC mode. Though the current becomes stable after the CC mode is activated, the current spike occurred at the CV and CC crossover point may possibly damage the DUT. At the power output-on stage, the PSW-Series is able to run under CC priority to limit the current spike occurred at the threshold voltage and therefore protect DUT from the inrush current damage.

The adjustable slew rate of the PSW-Series allows user to set for either output voltage or output current a specific rise time at the low to high level transition, and a specific fall time at the high to low level transition. This facilitates the characteristic verification of a DUT during voltage or current level changes with controllable slew rates. The manufacturing tests of lighting device or large capacitor during power output-on are mostly associated with the occurrence of high surge current, which can greatly reduce the life time of the DUT. To prevent inrush current from damaging current-intensive devices, a smooth and slow voltage transition during power on-off can significantly reduce the spike current and protect the device from high current damage.

The OVP and OCP are provided with the PSW-Series. Both OVP and OCP levels can be selected, with default level set at 110%, of the rated voltage/current of the power supply. When any of the protection level is tripped, the power output will be switched off to protect the DUT. The PSW-Series provides USB Host/Device and LAN interfaces as standard and GPIB-USB adaptor as optional. The LabView driver and the Data Logging PC software are supported on all the available interfaces. An analog control/monitoring connector is also available on the rear panel for external control of power On/Off and external monitoring of power output Voltage and Current.

Need more information?

Please contact +6221-5467618, +6221-54212399 or email [email protected]

Specification

PSW-360W
Model PSW 30-36 80-13.5 160-7.2 250-4.5 800-1.44
Rated Output Voltage V 30 80 160 250 800
Rated Output Current A 36 13.5 7.2 4.5 1.44
Rated Output Power W 360 360 360 360 360
Power Ratio 3 3 3.2 3.125 3.2
Constant Voltage Mode PSW 30-36 80-13.5 160-7.2 250-4.5 800-1.44
Line Regulation (*1) mV 18 43 83 128 403
Load Regulation (*2) mV 20 45 85 130 405
Ripple and Noise (*3)
  p-p (*4) mV 60 60 60 80 150
  r.m.s (*5) mV 7 7 12 15 30
Temperature coefficient ppm/°C 100ppm/°C of rated output voltage, after a 30 minute warm-up.
Remote sense compensation voltage V/wire 0.6 0.6 0.6 1 1
Rise Time (*6)
  Rated Load ms 50 50 100 100 150
  No Load ms 50 50 100 100 150
Fall Time (*7)
  Rated Load ms 50 50 100 150 300
  No Load ms 500 500 1000 1200 2000
Transient response time (*8) ms 1 1 2 2 2
Constant Current Mode PSW 30-36 80-13.5 160-7.2 250-4.5 800-1.44
Line regulation (*1) mA 41 18.5 12.2 9.5 6.44
Load regulation (*9) mA 41 18.5 12.2 9.5 6.44
Ripple and noise
  r.m.s (*5 ) mA 72 27 15 10 5
Temperature coefficient ppm/°C 200ppm/°C of rated output current, after a 30 minute  warm-up.
Protection Function PSW 30-36 80-13.5 160-7.2 250-4.5 800-1.44
Over voltage protection (OVP)
  Setting range V 3-33 8-88 16-176 20-275 20-880
  Setting accuracy   ± (2% of rated output voltage)
Over current protection (OCP)
  Setting range A 3.6-39.6 1.35-14.85 0.72-7.92 0.45-4.95 0.144-1.584
  Setting accuracy   ± (2% of rated output current)
Over temperature protection (OTP)
  Operation   Turn the output off.
Low AC input protection (AC-FAIL)
  Operation   Turn the output off.
Power limit (POWER LIMIT)
  Operation   Over power limit.
  Value (fixed)   Approx. 105% of rated output power
Front Panel PSW 30-36 80-13.5 160-7.2 250-4.5 800-1.44
Display, 4 digits
  Voltage accuracy 0.1% + mV 20 20 100 200 400
  Current accuracy 0.1% + mA 40 20 5 5 2
Programming and Measurement (Interface) PSW 30-36 80-13.5 160-7.2 250-4.5 800-1.44
Voltage programming accuracy 0.1% + mV 10 10 100 200 400
Current programming accuracy 0.1% + mA 30 10 5 5 2
Voltage programming resolution mV 1 2 3 5 14
Current programming resolution mA 1 1 1 1 1
Voltage measurement accuracy 0.1% + mV 10 10 100 200 400
Current measurement accuracy 0.1% + mA 30 10 5 5 2
Voltage measurement resolution mV 1 2 3 5 14
Current measurement resolution mA 1 1 1 1 1
               
PSW-720W
Model PSW 30-72 80-27 160-14.4 250-9 800-2.88
Rated Output Voltage V 30 80 160 250 800
Rated Output Current A 72 27 14.4 9 2.88
Rated Output Power W 720 720 720 720 720
Power Ratio 3 3 3.2 3.125 3.2
Constant Voltage Mode PSW 30-72 80-27 160-14.4 250-9 800-2.88
Line Regulation (*1) mV 18 43 83 128 403
Load Regulation (*2) mV 20 45 85 130 405
Ripple and Noise (*3)
  p-p (*4) mV 80 80 80 100 200
  r.m.s (*5) mV 11 11 15 15 30
Temperature coefficient ppm/°C 100ppm/°C of rated  output voltage, after a 30 minute warm-up.
Remote sense compensation voltage V/wire 0.6 0.6 0.6 1 1
Rise Time (*6)
  Rated Load ms 50 50 100 100 150
  No Load ms 50 50 100 100 150
Fall Time (*7)
  Rated Load ms 50 50 100 150 300
  No Load ms 500 500 1000 1200 2000
Transient response time (*8) ms 1 1 2 2 2
Constant Current Mode PSW 30-72 80-27 160-14.4 250-9 800-2.88
Line regulation (*1) mA 77 32 19.4 14 7.88
Load regulation (*9) mA 77 32 19.4 14 7.88
Ripple and noise
  r.m.s (*5 ) mA 144 54 30 20 10
Temperature coefficient ppm/°C 200ppm/°C of rated output current, after a 30 minute warm -up.
Protection Function PSW 30-72 80-27 160-14.4 250-9 800-2.88
Over voltage protection (OVP)
  Setting range V 3-33 8-88 16-176 20-275 20-880
  Setting accuracy   ± (2% of rated output voltage)
Over current protection (OCP)
  Setting range A 5-79.2 2.7-29.7 1.44-15.84 0.9-9.9 0.288-3.168
  Setting accuracy   ± (2% of rated output current)
Over temperature protection (OTP)
  Operation   Turn the output off.
Low AC input protection (AC-FAIL)
  Operation   Turn the output off.
Power limit (POWER LIMIT)
  Operation   Over power limit.
  Value (fixed)   Approx. 105% of rated output power
Front Panel PSW 30-72 80-27 160-14.4 250-9 800-2.88
Display, 4 digits
  Voltage accuracy 0.1% + mV 20 20 100 200 400
  Current accuracy 0.1% + mA 70 40 30 10 4
Programming and Measurement (Interface) PSW 30-72 80-27 160-14.4 250-9 800-2.88
Voltage programming accuracy 0.1% + mV 10 10 100 200 400
Current programming accuracy 0.1% + mA 60 30 15 10 4
Voltage programming resolution mV 1 2 3 5 14
Current programming resolution mA 2 2 2 1 1
Voltage measurement accuracy 0.1% + mV 10 10 100 200 400
Current measurement accuracy 0.1% + mA 60 30 15 10 4
Voltage measurement resolution mV 1 2 3 5 14
Current measurement resolution mA 2 2 2 1 1
               
PSW-1080W
Model PSW 30-108 80-40.5 160-21.6 250-13.5 800-4.32
Rated Output Voltage V 30 80 160 250 800
Rated Output Current A 108 40.5 21.6 13.5 4.32
Rated Output Power W 1080 1080 1080 1080 1080
Power Ratio 3 3 3.2 3.125 3.2
Constant Voltage Mode PSW 30-108 80-40.5 160-21.6 250-13.5 800-4.32
Line Regulation (*1) mV 18 43 83 128 403
Load Regulation (*2) mV 20 45 85 130 405
Ripple and Noise (*3)
  p-p (*4) mV 100 100 100 120 200
  r.m.s (*5) mV 14 14 20 15 30
Temperature coefficient ppm/°C 100ppm/°C of ra ted output voltage, after a 30 minute warm-up.
Remote sense compensation voltage V/wire 0.6 0.6 0.6 1 1
Rise Time (*6)
  Rated Load ms 50 50 100 100 150
  No Load ms 50 50 100 100 150
Fall Time (*7)
  Rated Load ms 50 50 100 150 300
  No Load ms 500 500 1000 1200 2000
Transient response time (*8) ms 1 1 2 2 2
Constant Current Mode PSW 30-108 80-40.5 160-21.6 250-13.5 800-4.32
Line regulation (*1) mA 113 45.5 26.6 18.5 9.32
Load regulation (*9) mA 113 45.5 26.6 18.5 9.32
Ripple and noise
  r.m.s (*5 ) mA 216 81 45 30 15
Temperature coefficient ppm/°C 200ppm/°C of rated output current, after a 30 minute warm-up .
Protection Function PSW 30-108 80-40.5 160-21.6 250-13.5 800-4.32
Over voltage protection (OVP)
  Setting range V 3-33 8-88 16-176 20-275 20-880
  Setting accuracy   ± (2% of rated output voltage)
Over current protection (OCP)
  Setting range A 5-118.8 4.05-44.55 2.16-23.76 1.35-14.85 0.432-4.752
  Setting accuracy   ± (2% of rated output current)
Over temperature protection (OTP)
  Operation   Turn the output off.
Low AC input protection (AC-FAIL)
  Operation   Turn the output off.
Power limit (POWER LIMIT)
  Operation   Over power limit.
  Value (fixed)   Approx. 105% of rated output power
Front Panel PSW 30-108 80-40.5 160-21.6 250-13.5 800-4.32
Display, 4 digits
  Voltage accuracy 0.1% + mV 20 20 100 200 400
  Current accuracy 0.1% + mA 100 50 30 20 6
Programming and Measurement (Interface) PSW 30-108 80-40.5 160-21.6 250-13.5 800-4.32
Voltage programming accuracy 0.1% + mV 10 10 100 200 400
Current programming accuracy 0.1% + mA 100 40 20 15 6
Voltage programming resolution mV 1 2 3 5 14
Current programming resolution mA 3 3 3 1 1
Voltage measurement accuracy 0.1% + mV 10 10 100 200 400
Current measurement accuracy 0.1% + mA 100 40 20 15 6
Voltage measurement resolution mV 1 2 3 5 14
Current measurement resolution mA 3 3 3 1 1
               
Common Specification
Input Characteristics PSW 30V 80V 160V 250V 800V
Nominal input rating   100Vac to 240Vac, 50Hz to 60Hz, single phase
Input voltage range   85Vac ~ 265Vac
Input voltage range   47Hz ~ 63Hz
Maximum input current
  100Vac A 360W: 5A, 720W: 10A, 1080W: 15A
  200Vac A 360W: 2.5A, 720W: 5A, 1080W: 7.5A
Inrush current A < 25A for 360W, < 50A for 720W, < 75A for 1080W
Maximum input power VA 360W: 500VA, 720W: 1000VA, 1080W: 1500VA
Power factor
  100Vac   0.99
  200Vac   0.97
Efficiency
  100Vac % 77 78 79 79 80
  200Vac % 79 80 81 81 82
Hold-up time   20ms or greater
Analog Programming and Monitoring PSW 30V 80V 160V 250V 800V
External voltage control output voltage   Accuracy and linearity: ±0.5% of rated output voltage.
External voltage control output current   Accuracy and linearity: ±1% of rated output current.
External resistor control output voltage   Accuracy and linearity: ±1.5% of rated output voltage.
External resistor control output current   Accuracy and linearity: ±1.5% of rated output current.
Output voltage monitor
  Accuracy % ±1 ±1 ±1 ±2 ±2
Output current monitor
  Accuracy % ±1 ±1 ±1 ±2 ±2
Shutdown control   Turns the output off with a LOW (0V to 0.5V) or short-circuit.
Output on/off control   Possible logic selections:
Turn the output on using a LOW (0V to 0.5V) or short-circuit, turn the output off using a HIGH (4.5V to 5V) or open-circuit.
Turn the output on using a HIGH (4.5V to 5V) or open-circuit, turn the output off using a LOW (0V to 0.5V) or short-circuit.
CV/CC/ALM/PWR ON/OUT ON indicator   Photocoupler open collector output; Maximum voltage 30V, maximum sink current 8mA.
Series and Parallel Capability PSW 30V 80V 160V 250V 800V
Parallel number Units 3 3 3 3 3
Series Number Units 2 2 2 None None
Front Panel
Indications   GREEN LED’s:
CV, CC, VSR, ISR, DLY, RMT, 20, 40, 60, 80, 100, %W, W, V, A
RED LED’s: ALM
Buttons   Function, OVP/OCP, Set, Test, Lock/Local, PWR DSPL, Output
Knobs   Voltage, Current
USB port   Type A USB connector
Interface Capabilities
USB   TypeA: Host, TypeB: Slave, Speed: 1.1/2.0, USB Class: CDC(Communications Device Class)
LAN   MAC Address, DNS IP Address, User Password, Gateway IP Address, Instrument IP Address, Subnet Mask
GPIB   Optional: GUG-001 (GPIB to USB Adapter)
Environmental Conditions
Operating temperature   0˚C to 50˚C
Storage temperature   -25˚C to 70˚C
Operating humidity   20% to 85% RH; No condensation
Storage humidity   90% RH or less; No condensation
Altitude   Maximum 2000m
General Specifications
Weight (main unit only) kg Approx. 3kg for 360W,
Approx. 5.3kg for 720W,
Approx. 7.5kg for 1080W
Dimensions (WxHxD) mm3  360W: 71×124×350mm,
720W: 142×124×350mm,
1080W: 214×124×350mm
Cooling   Forced air cooling by internal fan.
EMC   Complies with the European EMC directive 2004/108 /EC for Class A test and measurement products.
Safety   Complies with the European Low Voltage Directive 2006 /95/EC and carries the CE-marking.
Withstand voltage   Between input and chassis: No abnormalities at 1500 Vac for 1 minute.
Between input and output: No abnormalities at 3000 Vac for 1 minute.
Between output and chassis:
No abnormalities at 500 Vdc for 1 minute for 30V, 80V, 160V models.
No abnormalities at 1500 Vdc for 1 minute for 250V, 800V models.  
Insulation resistance   Between input and chassis: 500 Vdc, 100MΩ or more
Between input and output: 500 Vdc, 100MΩ or more
Between output and chassis:
500 Vdc, 100MΩ or more for 30V, 80V, 160V and 250V models.
1000Vdc, 100MΩ or more for 800V models.  

 

Notes
*1: At 85 ~ 132Vac or 170 ~ 265Vac, constant load.
*2: From No-load to Full-load, constant input voltage. Measured at the sensing point in Remote Sense.
*3: Measure with JEITA RC-9131B (1:1) probe
*4: Measurement frequency bandwidth is 10Hz to 20MHz.
*5: Measurement frequency bandwidth is 5Hz to 1MHz.
*6: From 10% to 90% of rated output voltage, with rated resistive load.
*7: From 90% to 10% of rated output voltage, with rated resistive load.
*8: Time for output voltage to recover within 0.1% + 10mV of its rated output for a load change from 50 to 100% of its rated output current.
*9: For load voltage change, equal to the unit voltage rating, constant input voltage.