LECROY – PeRT3 Eagle System

Developed through the synergy of Teledyne LeCroy’s electrical test and protocol test technologies, the PeRT3 test system combines the functions and features of a signal generator, bit error rate tester (BERT), protocol editor and data analysis system in one instrument.

Developed through the synergy of Teledyne LeCroy’s electrical test and protocol test technologies, the PeRT3 test system combines the functions and features of a signal generator, bit error rate tester (BERT), protocol editor and data analysis system in one instrument. This combination provides the ability to fully automate testing of transceivers and electronic systems in a comprehensive manner that not only measures adherence to specifications, but also examines the entire performance envelope of the system under test.

Need more information?

Please contact +6221-5467618, +6221-54212399 or email [email protected]

Specification

Generator Data Out
Bit Rate 622 Mb/s to 6 Gb/s
Data Format NRZ, normal or inverted
Rise/Fall Time (20–80%) 34 psec typical
Programmable Rise/Fall Time Yes
Max. Rise/Fall Time Mismatch 0.05 UI
Differential Amplitude Range 50 mV to 1.8V, 5 mV steps
Voltage Offset -2 V to +2.5 V
Maximum AC Common Mode Voltage 20 mV
Maximum Intrinsic Jitter < 20 psec typical
Tri-state Outputs Yes
Electrical Idle Generation Yes
SSC Support Yes
Pre/De-emphasis Support Yes
Return Loss SDD11 and S11 < -10 dB over entire frequency range
Generator Clock Out
Frequency Range 100 MHz to 6 GHz
Rise/Fall Time (20–80%) 34 psec typical
Voltage Rails AC coupled
Jitter 1 psec RMS typical
Amplitude Range CML
Sub-rate Clock Divide by 1, or divide by any number between 8 and 511 (and multiplied by 1, 2, 4, or 8)
Jitter Stress Yes
Protocols Supported
PCI Express 2.5 and 5 Gb/s
SAS 1.5, 3 and 6 Gb/s
SATA 1.5, 3 and 6 Gb/s
USB 3.0 5 Gb/s
Generator Jitter Stress
1.5 MHz – 100 MHz RMS Jitter 17 psec
10 KHz – 1.5 MHz RMS Jitter 17 psec
1.5 MHz – 100 MHz Dj P-P 240 psec
10 KHz – 1.5 MHz Dj P-P 240 psec
Periodic Jitter Integrated and Calibrated
Sinusoidal Jitter Integrated and Calibrated
Random Jitter Integrated and Calibrated
Sine Interference Integrated and Calibrated
Total Jitter > 1 UI at high frequency, 10s of UIs at low frequency
External Jitter Injection Yes
Error Detector Data In
Differential Amplitude Range 75 mV to 1.8 V
Format NRZ

Downloads